The website uses cookies to make the website work properly and improve your experience. More information can be found in Cookie policy.
ERROR: Turbine doors - Not closed in time (XXX)
ERROR: Turbine doors - Not closed in time (XXX)
The alarm occurs if the PLC controller does not detect the cylinder input within the expected time, after the door closing output has been activated.
- The pneumatic cylinders for opening and closing the throwing wheels doors are located on top of the machine.
- Check air pressure on the manometer. The set pressure must be 5 bar. In the pneumatic cabinet, check if the corresponding valve is activated. The valves have an LED activity indicator.
Check the operation of the magnetic position switches on the pneumatic cylinder. The LED indicator on the switch must be switched on at the limit positions. Adjust the switch position if necessary. The actual status of the switch inputs on the cylinder can be checked on the status screen; "THROWING WHEELS DOORS".
If you need additional information, call the Gostol TST service department.
Žarko Rejec
M: 00386 40 725 594
E: zarko.rejec@gostol-tst.eu