ERROR: No signal from impulse transmitor (-BXX.X)
ERROR: No signal from impulse transmitor (-BXX.X)
The roller motor was turned on, but the actual rotation of the rollers was not detected. The rotation of the rollers is controlled by an inductive switch that counts the pulses of the star, which is placed on one of the rollers (it is hidden under a protective cover). A star of 12 points and during rotation inductive sensor must detect all passage of metal through (sensor reach is 3 mm).
If the sensor works, we check in the "TRANSPORT" status screens. When the inductive switch is covered, the red cross turns into a green check mark.
If you need additional information, call the Gostol TST service department.
Žarko Rejec
M: 00386 40 725 594
E: zarko.rejec@gostol-tst.eu