ERROR: Snifter dust monitor over alarm level (XXX)

The Snifter S101 Dust Monitor measures the dust level in a gas flow by using inductive electrification technology which is based on AC measurement of moving particles which carry a charge. 

dust monitor

There are two alarm signal outputs to indicate two different alarm conditions. In addition to this, the front cover illumination will blink to inform about the current alarm condition. 

  • The proportion of dust particles in the air behind the machine filter exceeds 20 times the value measured with new filter cartridges.
  •  When this error is present, the machine must not work!
  • Check and replace the filter cartridges.

If you need additional information, call the Gostol TST service department.