WARNING: Doors - Not opened in time (XXX)
WARNING: Doors - Not opened in time (XXX)
The alarm occurs if the PLC controller does not detect the right or left door open input within the expected time, after the door opening output is activated. The left and right wings opens separately, the order depends on which wing has the cover edge.
- Check air pressure on the manometer. The set pressure must be 5 bar. In the pneumatic cabinet, check if the corresponding valve is activated. The valves have an LED activity indicator.
- Check the switches that control the openness of the left and right wings.
If you need additional information, call the Gostol TST service department.