WARNING: Doors - Not opened in time (XXX)

The alarm occurs if the PLC controller does not detect the right or left door open input within the expected time, after the door opening output is activated. The left and right wings opens separately, the order depends on which wing has the cover edge.

  • Check air pressure on the manometer. The set pressure must be 5 bar. In the pneumatic cabinet, check if the corresponding valve is activated. The valves have an LED activity indicator.

pneumatic cabinet

  • Check the switches that control the openness of the left and right wings.

switches for door wings

If you need additional information, call the Gostol TST service department.
Žarko Rejec
M: 00386 40 725 594
E:
zarko.rejec@gostol-tst.eu

The website uses cookies to make the website work properly and improve your experience. More information can be found in Cookie policy.