ERROR: The name of the drive that the inverter is driving - Not enabled (-XX.X)

ERROR: The name of the drive that the inverter is driving - Not enabled (-XX.X)

The frequency inverter sends to PLC controller information, that it has no operating condition.

  • Check if the frequency inverter has a suitable main power supply.
  • Check the inverter's safety input, 24VDC.
    • Danfoss, on connection points 37 and 38 must be 24V.

inverter's safety input

    • Siemens, on connection points 16 and 17, must be 24V.

inverter's safety input

  • Place a portable display on the inverter and check the operating mode of the inverter.

    • Danfoss, press the "Auto On" button so that the led indicator above the button lights up.

inverter

    • Siemens, select the automatic mode with the "HAND/AUTO" key.

inverter

If you need additional information, call the Gostol TST service department.