ERROR: Hydraulic cylinder - Did not reach low position (-XXX)
ERROR: Hydraulic cylinder - Did not reach low position (-XXX)
The alarm occurs if the PLC controller does not detect hydraulic cylinder low position input within the expected time, when the hydraulic cylinder lowering commands is set.
- Check if the hydraulic pump motor is working. Check oil pressure on the manometer. Check if the corresponding valve is activated. The valves have an LED activity indicator.
- Check states of cylinders position switches.
- The actual status of the switch inputs on the cylinder can be checked on the status screen; “CHARGING SYSTEM”.
If you need additional information, call the Gostol TST service department.
Žarko Rejec
M: 00386 40 725 594
E: zarko.rejec@gostol-tst.eu