ERROR: No signal from impulse transmitor (-BXX.X)

The motor was turned on, but the actual rotation of the wire mesh was not detected. The rotation of the wire mesh is controlled by an inductive switch that counts the pulses of the star, which is placed on one of the drive rollers (it is hidden under a protective cover). A star of 12 points and during rotation inductive sensor must detect all passage of metal through (sensor reach is 3 mm).

  • Check the chain between the motor and the drive roller.

Ni signala števca impulzov

If the sensor works, we check the "TRANSPORT" status screens. When the inductive switch is covered, the red cross turns into a green check mark.

Ni signala števca impulzov

If you need additional information, call the Gostol TST service department.
Žarko Rejec
M: 00386 40 725 594
E:
zarko.rejec@gostol-tst.eu