ERROR: Turbine control cage - Wire break (-MXX.X)

The analog signal of the turbine control cage valve is outside the intended range.

  • Actuator measures its position with an analog output of DC voltage 0 to 10V.
  • Check the operation of the valve in the manual mode. When we press the "-" button, the valve should move to minimum degrees, when we hold the "+" button, the valve should increase to maxim degrees. 

pomik končnika turbine

  • We monitor the movement of the actuator on turbine and if the actual degrees on the turbine match those shown on the screen.

končnik turbine

If you need additional information, call the Gostol TST service department.