ERROR: Turbine doors - Not closed in time (XXX)

The alarm occurs if the PLC controller does not detect the cylinder input within the expected time, after the door closing output has been activated.

  • The pneumatic cylinders for opening and closing the throwing wheels doors are located on top of the machine.

pneumatic cylinders

  • Check air pressure on the manometer. The set pressure must be 5 bar. In the pneumatic cabinet, check if the corresponding valve is activated. The valves have an LED activity indicator.

pneumatic cabinet

Check the operation of the magnetic position switches on the pneumatic cylinder. The LED indicator on the switch must be switched on at the limit positions. Adjust the switch position if necessary. The actual status of the switch inputs on the cylinder can be checked on the status screen; "THROWING WHEELS DOORS".

throwing wheels doors

If you need additional information, call the Gostol TST service department.