WARNING: Doors - Not closed in time (XXX)
WARNING: Doors - Not closed in time (XXX)
The alarm occurs if the PLC controller does not detect the right or left door closed input within the expected time, after the door closing output is activated. The left and right wings close separately, the order depends on which wing has the cover edge.
- Check air pressure on the manometer. The set pressure must be 5 bar. In the pneumatic cabinet, check if the corresponding valve is activated. The valves have an LED activity indicator.
- Check the switches that control the closure of the left and right wings.
If you need additional information, call the Gostol TST service department.